FLIR A310 EX

ATEX-Compliant IR Temperature Sensors

Explosive atmospheres need to be protected from ignition sources. Selecting equipment and protective systems which meet the requirements of the ATEX Product Regulations or similar regulations is essential. FLIR A310 ex is an ATEX compliant solution, with a thermal imaging camera mounted in an enclosure, making it possible to monitor critical and other valuable assets also in explosive atmospheres. Typical applications for the A310 ex include process monitoring, quality control, and fire detection in explosive locations. Because the FLIR A310 ex is rated IP 67, it can be installed in dusty environments. The Flame-Proof Enclosure “d”prevents any explosion transmission from the inside of the enclosure to the outside.

SPECIFICATIONS

Ethernet Video Streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
ATEX certification (version-AXC) EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
f-number 1.3
Image Frequency 30 Hz
Thermal Sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Accuracy ±2°C (±3.6°F) or ±2% of reading
Alarm Functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output Digital Out, log, store image, file sending (ftp), email (SMTP), notification

COMMUNICATION & DATA STORAGE

Ethernet Control, result and image
Ethernet Communication TCP/IP socket-based FLIR proprietary
Ethernet Configuration Pigtail with FC-connector (fiber)
Ethernet Image Streaming 16-bit 320 × 240 pixels @ 7-8 Hz – Radiometric
Ethernet Medium Multi-mode breakout fiber AT-V(ZN)Y(ZN)Y 4G50/125 OM2
Ethernet Protocols Ethernet/IP, Modbus TCP, TCP, UDP, SNTP, RTSP, RTP, HTTP, ICMP, IGMP, ftp, SMTP, SMB (CIFS), DHCP, MDNS (Bonjour), uPnP
Ethernet Standard 100 Mbps / IEEE 802.3
Ethernet Video Streaming MPEG-4, ISO/IEC 14496-1 MPEG-4 ASP@L5
File Formats Standard JPEG, 16-bit measurement data included
Length of Ethernet cable 4 m (13 ft.)
Power Cable & Configuration Helukabel 37264 / Pigtail
Storage Media Built-in memory for image storage

IMAGING & OPTICAL

Color Palettes Color palettes (BW, BW inv, Iron, Rain)
Detector Pitch 25 µm
Detector Time Constant Typical 12 ms
Detector Type Focal Plane Array (FPA), uncooled microbolometer
Field of view (FOV) – Focal Length 25° × 18.8° with 18 mm (0.7 in.) lens
FLIR Screen-EST Mode No
f-number 1.3
Focus Automatic or manual (built in motor)
Image Frequency 30 Hz
IR Resolution 320 × 240 pixels
Lens Identification Automatic
Minimum Focus Distance 0.4 m (1.31 ft.)
Spatial resolution (IFOV) 1.36 mrad with 25° lens
Spectral Range 7.5–13 µm
Thermal Sensitivity/NETD < 0.05°C @ +30°C (+86°F) / 50 mK
Zoom 1–8× continuous, digital, interpolating zooming on images

MEASUREMENT & ANALYSIS

Accuracy ±2°C (±3.6°F) or ±2% of reading
Alarm Functions 6 automatic alarms on any selected measurement function, Digital In, Camera temperature, timer
Alarm Output Digital Out, log, store image, file sending (ftp), email (SMTP), notification
Area 10 boxes with max./min./average/position
Atmospheric transmission correction Automatic, based on inputs for distance, atmospheric temperature and relative humidity
Difference Temperature Delta temperature between measurement functions or reference temperature
Emissivity Correction Variable from 0.01 to 1.0
External Optics & Windows Correction Automatic, based on input of optics/window transmission and temperature
Isotherm 1 with above/below/interval
Measurement Corrections Global and individual object parameters
Measurement Option Measurement Mask Filter Schedule response: File sending (ftp), email (SMTP)
Object Temperature Range –20 to +120°C (–4 to +248°F) 0 to +350°C (+32 to +662°F)
Optics Transmission Correction Automatic, based on signals from internal sensors
Reference Temperature Manually set or captured from any measurement function
Reflected apparent temperature correction Automatic, based on input of reflected temperature
Set-up Commands Date/time, Temperature°C/°F
Spot Meter 10.0

GENERAL

Contents Infrared camera with lens, in explosion-proof housing, cardboard box, Printed documentation, User documentation CD-ROM, Utility CD-ROM
Empty Volume 5.06 l
External Dimensions [without sun shield] D = 170 mm, L = 408 mm
Housing material & Surface Nickel-plated aluminium / Powder coated
Integrated Controller 4-port switch with 2 × fiber-optic LC 100Base-FX or 2 × RJ45(10/100) up-links, ring-topology support for reduced cabling effort, 2 × internal temperature sensors, air humidity and pressure sensor, digital output module controllable via Modbus TCP/IP or web interface to enable turning the heater on/off
Packaging Size 495 x 370 x 192 mm (19.5 x 14.6 x 7.6 in.)
Protection Window Germanium, double-sided AR Coated, externally with additional hard-carbon layer
Weight 6.7 kg (without camera and lens)

ENVIRONMENTAL & CERTIFICATIONS

Ambient temperature range for operation –40°C to 60°C (-40°F to 140°F)
ATEX certification (version-AXC) EX-Protection Gas: II 2G Ex d IIC T6 Gb, EX-Protection Dust: II 2D Ex tb IIC T85° Db
For use in EX zone 1, 2, 21, and 22
Ignition protection category Flame-proof enclosure “d”
Maximum Surface Temp [temp class T6] Maximum 85°C
Protection Class IP67
Verification Certificate ZELM 12 ATEX 0485 X

POWER

Length of Power Cable 4 m (13 ft.)
Maximum Electric Connection Power 60 W
Maximum power of the Additional Heater 16 W
Operating Voltage 24 V DC